200KW Portable AC Resistive Load Bank EV Charger UPS Generator Inverter
200KW Portable AC resistive load bank (SP-AC400V-200KW-R): local touch screen and remote control host software via PC, 1KW min. load step, four wheels for easy movement, suitable for UPS, generator, inverter and power testing.
About 520*920*868mm
About 137KG
SP-AC400V-200KW-R
Introduction:
SP-R AC single/three-phase resistive load bank, the power input adopts segmented combination control, unified segmented power input, supports sudden addition/unloading, the load adopts energy-consuming working mode, forced air cooling type heat dissipation, The reliability of constant power discharge is greatly ensured. The new power consumption components are produced with independent intellectual property rights. They have high power density and no red hot phenomenon. The automatic overheating protection function prevents overheating and burnout in the unexpected situation where the fan does not rotate. condition, safe and long life.
The whole machine adopts a modular design, which is simple to operate and maintain. It can measure voltage, current and other parameters according to customer requirements, providing a scientific detection method for high-power AC power equipment and meeting the full load detection of inverters, UPS power supplies, generator sets, etc. It is a necessary testing tool for production workshops, laboratories, installation and debugging, and scientific research and development.
Features:
Specification:
Product Name | SP-AC400V-200KW-R Three-phase AC Resistive Load Bank (Portable) |
Rated Voltage | AC400V, 3P4W, 50/60Hz |
Rated Power | R= 200KW |
Power factor | PF=1 |
Load steps resolution | Min. steps is 1KW |
Load test accuracy | ±5% |
Protection function | Over-voltage/ over-current/ over-temperature protection, E-stop protection |
Work power | Single-phase AC230, 50/60Hz (Power cord input) |
Work Mode | Continuous work |
Cooling Mode | Force-air cooling; air entry from bottom and outlet from top |
Control mode | Local touch screen & Remote control host computer software via PC |
Wiring method | Quick plug connector wiring |
Move mode | Four wheels |
Ambient Temperature | -10℃~+50℃ |
Humidity | ≤90% |
Max protection grade | IP20 (for Indoor use) |
Dimension (W*D*H) | About 520*920*868mm (Size is subject to finished device) |
Net Weight | About 137KG (Weight is subject to finished device) |
Language | English (Default) |
Material | Alloy resistor (high temperature resistant which can work up to 1300℃ with stable electrical performance and small temperature drift coefficient (5*10-5/℃) |
Remarks: Special specifications can be customized according to customer requirements (Rated voltage, Rated power, Power supply voltage, box size etc).
Other similar products:
Model No. | Description |
AC Resistive Load Bank | |
R-3KW | 3KW Resistive AC load bank |
R-5KW | 5KW Resistive AC load bank |
R-10KW | 10KW Resistive AC load bank |
R-20KW | 20KW Resistive AC load bank |
R-30KW | 30KW Resistive AC load bank |
R-50KW | 50KW Resistive AC load bank |
R-60KW | 60KW Resistive AC load bank |
R-100KW | 100KW Resistive AC load bank |
R-150KW | 150KW Resistive AC load bank |
R-200KW | 200KW Resistive AC load bank |
R-250KW | 250KW Resistive AC load bank |
R-300KW | 300KW Resistive AC load bank |
R-400KW | 400KW Resistive AC load bank |
R-500KW | 500KW Resistive AC load bank |
R-600KW | 600KW Resistive AC load bank |
R-800KW | 800KW Resistive AC load bank |
R-1000KW | 1000KW Resistive AC load bank |
R-1500KW | 1500KW Resistive AC load bank |
R-2000KW | 2000KW Resistive AC load bank |
R-3000KW | 3000KW Resistive AC load bank |
It applies a controlled resistive load for testing AC power sources such as diesel/gas generators, UPS systems, inverters and shore-power supplies — typically for commissioning, acceptance and periodic maintenance testing of units up to its rated kW (see the nameplate rating for your configuration).
Yes — portable resistive load banks of this type are the standard tool for on-site generator load testing. As a rule of thumb, size the load bank to 100–125% of the test requirement (see our load bank sizing guide for the 1.25 rule).
This series is operated from the local touch screen and can be controlled remotely from a PC via the supplied host software — you apply load in steps, monitor voltage/current, and record results for your test report.
Resistive load proves kW capability at unity power factor — sufficient for most generator and UPS kW tests. If your acceptance spec includes power-factor (e.g., 0.8 PF) testing, you need reactive capability; see our guide to resistive vs reactive vs electronic load banks.
Portable AC resistive load banks in this family are built on wheels for site movement with a forklift/crane lift point as standard for truck loading — confirm the exact dimensions, weight and lifting arrangement for the model you order.

Copy product links
Long by picture save/share


+86 13690182704
Monday to Friday
sales@smartpower-test.com
+852 30697480
Monday to Friday
sales@smartpower-test.com
Sophia