20KW DC Resistive Load Bank EV Charger Battery Power supply
20KW DC resistive load bank, local touch screen and remote control host computer software via PC, four wheel easy to move, suitable for UPS, Power, Generator, Inverter test etc.
About 600*750*1115mm
About 85KG
Introduction:
Features:
Specification:
Product Name | SP-DC1000V-20KW-R DC Resistive Load Bank |
Rated Voltage | DC1000V |
Rated Power | 20KW |
Load steps resolution | Min. steps is 0.1KW |
Load test accuracy | -5%~+2% |
Protection function | Over-voltage, over-current, over-temperature, fan phase sequence protection |
Work power | Single-phase AC220V, 50/60Hz (Power cord input) |
Work Mode | Continuous work |
Cooling Mode | Force-air cooling; air entry from bottom and outlet from top |
Control mode | Local touch screen & Remote control host computer software via PC |
Color of load bank | Optional (Orange/ Grey/ White) |
Move mode | Four wheels |
Ambient Temperature | -10℃~+50℃ |
Humidity | ≤90% |
Max protection grade | IP20 (for Indoor use) |
Dimension (W*D*H) | About 600*750*1115mm (Size is subject to finished device) |
Net Weight | About 85KG (Weight is subject to finished device) |
Language | English (Default) |
Material | Alloy resistor (high temperature resistant which can work up to 1300℃ with stable electrical performance and small temperature drift coefficient (5*10-5/℃) |
Remarks: Special specifications can be customized according to customer requirements (Rated voltage, Rated power, Power supply voltage, box size etc).
Other similar products:
Model No. | Description |
DC Resistive Load Bank | |
DC-10KW | 10KW DC load bank |
DC-20KW | 20KW DC load bank |
DC-30KW | 30KW DC load bank |
DC-40KW | 40KW DC load bank |
DC-60KW | 60KW DC load bank |
DC-100KW | 100KW DC load bank |
DC-150KW | 150KW DC load bank |
DC-200KW | 200KW DC load bank |
DC-300KW | 300KW DC load bank |
The 20KW DC Resistive Load Bank applies a controlled DC load to test DC power sources — batteries and battery strings, DC UPS, rectifiers, DC chargers and EV charger power stages — for capacity, discharge and maintenance testing.
Yes — constant-current or constant-resistance discharge at the required rate is the standard battery capacity test; confirm the model's current/voltage range and termination settings against your battery bank.
AC sources need AC load banks; DC sources (batteries, DC chargers) need DC units. For AC generator/UPS testing see our load bank type guide; choose DC for battery and DC charger work.
DC load banks are configured to a nominal DC voltage and rated discharge current/power — give us your battery or charger DC bus voltage and required discharge rate and we will match the model.